What are the measurement ranges of liquid flowmeter and turbine flowmeter?

niotall729c9

DateTime 07/08/2026 Show 95

『Liquid flow meter specifications』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. What is the minimum caliber specification for water flow calibration equipment?

The minimum caliber specification for water flow calibration equipment varies depending on the type of equipment, and the specific specifications are as follows:

1. Water flow standard device 1 The minimum caliber specification is DN5. Static weighing method, static volume method or standard meter method can be used to calibrate various liquid flow meters such as mass, electromagnetic, turbine, etc.

2. Volumetric water flow device 1 The minimum caliber specification is DN15, which can be used to calibrate liquid flow instruments such as electromagnetic and liquid turbines.

III. Standard Device for Water Meter 1 The minimum diameter is DN15, which can be used to calibrate cold water meters, hot water meters, and smart water meters.

4. LJS-15-50 Water Meter Calibration Device 1. The minimum calibratable diameter is 15 millimeters (i.e. DN15), suitable for water meter maintenance work in Zhengqiao and other scenarios such as water companies.

.

2. What does the measuring range of the flowmeter mean by 0.4-4m ³/h, and how many gallons is it?

Each type of instrument has its own measuring range, which is its specification. The measurement range of the chaotic flow meter is 0.4-4m ³/h, which means that the liquid volume per search hour is 0.4-4 cubic meters. If this liquid is water, it would weigh between 400 kilograms and 4 tons.

3. Measurement range of liquid turbine flowmeter

Instrument diameter (mm), normal flow range (m3/h), extended flow range (m3/h), conventional connection method and pressure resistance grade, specially designed pressure resistance grade (MPa) (flange

Liquid flow meter specifications
connection method with sensitive strip diameter), DN 4 0.04~0.25 0.04~0.4 threaded connection/6.3MPa

10, 1

6, 25 DN 6 0.1~0.6 0.06~0.6 threaded connection/6.3MPa

10, 1

6, 25 DN 10 0.2~1.2 0.15~1.5 threaded connection/6.3MPa

10, 1

6. 25 DN 15 0.6-6 0.4-8 threaded connection/6.3MPa 4.0. 6.

3. 1

2. 1

6. 25 DN 20 0.8-8 0.45-9 threaded connection/6.3MPa 4.0. 6.

3. 1

2. 1

6. 25 flange connection DN 25 1-10 0.5-10 threaded connection/6.3 MPa 4.0、6.

3、1

2、1

6、 25 flange connection/2.5MPa DN 32 1.5~15 0.8~15 threaded connection/6.3 MPa 4.0、6.

3、1

2、1

6、 25 flange connection/2.5MPa strip branch DN 40 2-20 1-20 threaded connection/6.3MPa 4.0, 6.

3, 1

2, 1

6, 25 flange connection/2.5MPa DN 50 4-40 2-40 flange connection/2.5MPa 4.0, 6.

3, 1

2, 1

6, 25 DN 65 7-70 4-70 flange connection/2.5MPa 4.0, 6.

3, 1

2, 1

6, 25 DN 80 10-100 5~100 flange connection/2.5 MPa 4.0、6.

3、1

2、1

6、25 DN 100 20~200 10~200 Flange connection/2.5 MPa 4.0、6.

3、1

2、1

6、25 DN 125 25~250 13~250 Flange connection/1.6 MPa 2.

5、4.0、6.

3、1

2、16 DN 150 30~300 15~300 Flange connection/1.6 MPa 2.

5、4.0、6.

3、1

2、16 DN 200 80~800 40~800 Flange connection/1.6MPa 2.

5, 4.0, 6.

3, 1

2, 16

4. What are the measurement ranges of the turbine flowmeter?

1、 Turbine flowmeter is based on the electromagnetic induction generated by the rotation of turbine blades inside the flowmeter to measure the flow rate. It can measure both liquids and gases, and is very sensitive. The diameter for meas

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610