『Methanol flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

What are the optional size specifications for methanol flow meters? The mainstream size specifications for methanol flow meters cover DN15~DN2000, which need to be determined based on the type of flow meter, operating flow rate, and pipeline parameters.
1. General size selection interval 1 Small flow scenarios: DN15~DN50, suitable for small diameter conveying scenarios such as sampling pipelines and small filling lines in workshops; 2. Medium flow scenario: DN65~DN300, which is the mainstream fitting size for the methanol main pipeline in the factory area; 3. High flow scenarios: DN350~DN2000, suitable for ultra large caliber working conditions such as dock unloading and long-distance methanol pipelines.
2. Size adaptation limitations for different types of flow meters: (1) Vortex flow meters: suitable for DN15~DN300, measurement accuracy will significantly decrease after exceeding DN300, and can only be used for measuring volume in non-conductive media (such as anhydrous methanol);
; (2) Electromagnetic flowmeter: suitable for DN10~DN2000, but can only be used for measuring industrial methanol containing trace conductive impurities. Anhydrous methanol cannot be used; (3) Coriolis mass flowmeter: suitable for DN10~DN300, with the highest measurement accuracy, mostly used in trade settlement scenarios, and relatively high cost; (4) Rotary flowmeter: only suitable for small flow sampling and measurement of DN15~DN50, mostly used in laboratories or trace conditions.III. Selection and Use Constraints 1 Flow range constraint: It is necessary to ensure that the actual working flow rate is within the optimal range ratio range of the selected flow meter (usually 10%~100% of the rated flow rate), in o
_600x400.jpg)
2. What are the measurement methods and conditions for methanol?
The commonly used methods for determining methanol are chromogenic acid colorimetry and gas chromatography.
. The sensitivity of the former can meet the requirements, but there are many interferences, such as ethanol, n-pentanol, sec butanol, acetone, and aldehydes, all of which have varying degrees of interference; The latter has less interference and can simultaneously measure methanol and ethanol.1. Gas Chromatography [
1,2] (1) Principle: Methanol in air is adsorbed on a silica gel sampling tube, washed with water, separated by a GDX-102 chromatographic column, and determined by a hydrogen flame ionization detector. Qualitative retention time and quantitative peak height are used.
. (2) Instrument (1) The sampling tube is a 90mm long glass tube with an inner diameter of 4mm. The front section is filled with 150mg silica gel, the rear section is filled with 50mg silica gel, the middle and rear end are filled with 3mm long polyurethane foam plastic, and the air inlet is filled with a small amount of glass wool. Both ends of the sampling tube are c